| Model |
DB200B(Standard Type) |
DB2000X(Small Type) |
DB2000Z(Medium Type) |
DB2000D(Large Type) |
| External dimension mm (L*W*H) |
7000*5100*3250 |
6200*4600*3150 |
7000*5100*3550 |
14000*5600*5050 |
| Internal dimension mm (L*W*H) |
6900*3900*2600 |
6100*3400*2500 |
6900*3900*2900 |
13900*4500*4400 |
| Air-change rotio (times/h) |
280 |
300 |
280 |
200 |
| Air-flow rate inside the booth,m/s |
0.3 |
0.35 |
0.3 |
0.3 |
| Max temperature,℃ |
80 |
80 |
80 |
80 |
| Temperature rise rate,20--60℃/min |
3--5 |
3--6 |
3--6 |
6--10 |
| Air filtering efficiency |
≥99 |
≥99 |
≥99 |
≥99 |
Oilconsumption.
kg/set/time |
4--5 |
3--4 |
5--6 |
10--12 |
| Noise,dB(A) |
<75 |
<75 |
<75 |
<80 |
| Total power consumption, Kw/h |
≤10 |
≤9 |
≤10 |
≤20 |
| Mode of electric control |
Intelligent computer programmed auto control |
| Remarks: |
Energy saving |
Energy saving |
Energy saving |
Standard |